PURE Marvella RO Specifications Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
24 25
FAqS
*The GKK-1/GKK-2 life of 400/800 hours approximately gives 4000/8000 litres of puried water under tested conditions
of 18 PSI input pressure, 450–500 ppm TDS and 25 °C temperature.
**Considering the device is used for 1 hour every day.
^The Germkill Kit™ (GKK-1/GKK-2) will be changed after every 400/800 hours respectively and there is an Auto Shut Off to
force this change. The Pre-Sediment Filter will be required to be replaced after approximately every 200 hours (approx 2000
litres). Depending on your water quality there may be a need to change the Pre-Sediment Filter before 200 hours.
PURITY
INDICATOR
TANK FULL
INDICATOR
TANK
FULL
TDS IN TDS OUT
TANK
FULL
G
K
K
1
G
K
K
2
Zero
Very low
Low
Moderate
High
Very high
Low
Moderate
Moderate
High
Very high
Extremely high
TDS range
represented
TDS range
represented
Germkill Kit 2
Life Indicator
Germkill Kit 1
Life Indicator
Purity
Indicator
Purity
Indicator
UNDERSTANDING THE DIGITAL
DISPLAY PANEL
CHANGE
GKK 1
CHANGE
GKK 2
GUIDED ALERT
SYSTEM
The central bars of the inner/outer indicator circle will
blink after ~185/~585 hours of usage respectively, to
prompt you to replace the Pre-Sediment Filter and it will
Auto Shut Off water at 200/600^ hours of usage respectively
if not replaced.
As the purier approaches ~385 hours of life, you will see the
last bar of the Germkill Kit 1 indicator blink, ‘CHANGE GKK’
blink at the centre of the Digital Display Panel and "CALL
1860-180-1000" illuminated at the bottom of the panel. On
completion of 400 hours* ‘CHANGE GKK’ will be static on
the panel. You would need to replace the Germkill Kit 1 by
contacting the Pureit Helpline at 1860-180-1000.
Blinking “Change GKK” - Alerts 15 days** before you
need to change Germkill Kit 1. Buy GKK 1.
Static “Change GKK” - Auto Shut Off of water.
Replace GKK 1.
As the purier approaches ~785 hours of life, you will see the
last bar of the Germkill Kit 2 indicator blink, ‘CHANGE GKK’
blink at the centre of the Digital Display Panel and "CALL
1860-180-1000" illuminated at the bottom of the panel. On
completion of 800 hours* ‘CHANGE GKK’ will be static on
the panel. You would need to replace the Germkill Kit 1 by
contacting the Pureit Helpline at 1860-180-1000.
Blinking “Change GKK” - Alerts 15 days** before you
need to change Germkill Kit 2. Buy GKK 2.
Static “Change GKK” - Auto Shut Off of water.
In case of specic electrical faults, a segment of the red band
will illuminate to indicate where the fault is.
How does Pureit Ultima RO + UV purify water?
Pureit Ultima RO + UV has a 6-Stage Purication System
which ensures you get water that is ‘As Safe As Boiled
Water™’ and also removes excess total dissolved solids
(TDS) to make your water tastier.
In the rst stage, the water passes through the
Pre-Sediment Filter which removes ne and coarse
particulate impurities/dirt.
The second stage is the Pre-RO Carbon Filter that
removes chlorine and organic impurities like harmful
pesticides. It also adsorbs bad taste and odour-causing
organic compounds from water.
The third stage is the Post-Carbon Sediment Filter which
removes the remaining dirt.
Then the water passes through the RO Membrane at
high pressure, with the help of an inbuilt pump. The RO
Membrane removes dissolved salts, hardness, pesticides
and heavy metals like arsenic, lead and mercury. It also
removes microbial contaminants like bacteria, virus,
protozoa and parasites.
After the RO Membrane, the water passes through a
TDS Modulator that adds adequate quantities of essential
minerals to the water.
Fifth stage is a high-intensity UV lamp that acts as an
additional stage of purication to further inactivate
bacteria, virus and parasites to deliver safe water.
Sixth and nal stage is the Post-RO Carbon Filter, which
acts as a polisher and enhances the taste of puried
water.
What is the storage capacity of ‘Pureit Ultima
RO + UV’?
Ultima RO + UV has a storage tank capacity of 10 litres
with running input water. With no continuous input
water, the average dispense capacity is 9.2 litres. The
process of lling the storage tank is fully automatic and
when you take water out of the tank, the purication
process automatically starts and rells the storage tank.
How much time it takes to purify water in ‘Pureit
Ultima RO + UV’?
‘Pureit Ultima RO + UV’ can purify water upto
9–12 litres per hour. However, the time taken to purify
depends on the life of the Filters, the input water
pressure, TDS and other impurities present in water.
How will I get new Consumables/Membranes
replaced?
You need to call the Pureit Helpline and order for a
Germkill Kit
TM
. Our technician will visit your place and
replace the Germkill Kit
TM
at a nominal cost.
Can I drink the rst purication cycle of water
from the purier?
After Pureit Ultima RO + UV is installed or whenever
the Germkill Kit (s) are replaced, discard the rst cycle
of water (10 litres) that is lled in the storage tank.
What should I do if there is no water being
dispensed from the tap?
In case you cannot dispense water from the tap, then
you need to rst check whether the power supply is
on. If it is on, then check if there are any fault indicators
illuminated, or "CHANGE Germkill Kit" and the Call
Centre Number is illuminated on the Digital Display
Panel. Call the Pureit helpline and get either the fault
resolved or Germkill Kit replaced.
If none of these lights are illuminated on the Digital
Display Panel, then check if the Ball Valve is closed.
If none of these cases are true, then please call Pureit
Helpline for assistance.
Can I open and service my purier?
It is not recommended to open and service device by an
individual. Call our Pureit Helpline if you face any issue
which requires servicing and opening the device.
Can I use any type of water to purify through
my Ultima RO + UV?
Pureit Ultima RO + UV will purify “potable” water for
removal of hardness and other impurities to give you safe
drinking water. If the input water has impurities normally
not present in drinking water (high iron/turbidity/
microbial contamination etc.) or water is from unknown
source (river/lake/pond/borewell etc.) then suitable
pre-treatments may be required.
SF CHANGE
INDICATOR
Replace GKK 2.
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18

Comments to this Manuals